Powered by Yanmar 4TNV98T
Emissions: Tier 4i EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 50 kVA / 40 kW
Prime Power Rating: 45 kVA / 36 kW
Powered by Iveco NEF45SM2X
Emissions: Tier 3 EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 75 kVA / 60 kW
Prime Power Rating: 67.5 kVA / 54 kW
Powered by Perkins 2806C-E18TTAG7
Emissions: Tier 2 EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 938 kVA / 750 kW
Prime Power Rating: 844 kVA / 675 kW
Leroy Somer Alternator
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Perkins 2206A-E13TAG6
Emissions: Tier 1 Rated, for International Use Only
60 Hz Power Rating at 3 Phase
Standby Power Rating: 500 kVA / 400 kW
Prime Power Rating: 438 kVA / 350 kW
Fuel Capacity 8-10 Hr
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Perkins 2506C-E15TAG3
Emissions: Tier 3 EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 625 kVA / 500 kW
Prime Power Rating: 569 kVA / 455 kW
Leroy Somer Alternator
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Perkins 2806C-E18TAG3
Emissions: Tier 2 EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 750 kVA / 600 kW
Prime Power Rating: 681 kVA / 545 kW
Leroy Somer Alternator
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Perkins 2206D-E13TAG3
Emissions: Tier 3 EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 506 kVA / 400 kW
Prime Power Rating: 456 kVA / 365 kW
Leroy Somer Alternator
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Perkins 2206D-E13TAG2
Emissions: Tier 3 EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 438 kVA / 350 kW
Prime Power Rating: 394 kVA / 315 kW
Leroy Somer Alternator
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Perkins 1706D-E93TAG2
Emissions: Tier 3 EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 375 kVA / 300 kW
Prime Power Rating: 338 kVA / 270 kW
Leroy Somer Alternator
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Perkins 1106D-E70TAG4
Emissions: Tier 3 EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 219 kVA / 175 kW
Prime Power Rating: 200 kVA / 160 kW
Leroy Somer Alternator
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Perkins 1106D-E70TAG5
Emissions: Tier 3 EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 250 kVA / 200 kW
Prime Power Rating: 225 kVA / 180 kW
Leroy Somer Alternator
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Perkins 1706D-E93TAG1
Emissions: Tier 3 EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 313 kVA / 250 kW
Prime Power Rating: 281 kVA / 225 kW
Leroy Somer Alternator
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Showing 1–12 of 243 results