Showing 1–12 of 28 results
Powered by Perkins 1506A-E88TAG5
Emissions: Tier 1 Rated, for International Use Only
50 Hz Power Rating at 3 Phase
Standby Power Rating: 335 kVA / 267 kW
Prime Power Rating: 300 kVA / 240 kW
Fuel Capacity 8-10 Hr
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Perkins 1506A-E88TAG5
Emissions: Tier 1 Rated, for International Use Only
60 Hz Power Rating at 3 Phase
Standby Power Rating: 388 kVA / 310 kW
Prime Power Rating: 350 kVA / 280 kW
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Perkins 1506A-E88TAG5
Emissions: Tier 1 Rated, for International Use Only
50 Hz Power Rating at 3 Phase
Standby Power Rating: 335 kVA / 267 kW
Prime Power Rating: 300 kVA / 240 kW
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by John Deere 6090CG550
Emissions: Tier 4 Final EPA-Certified for Mobile “NonRoad” Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 375 kVA / 300 kW
Prime Power Rating: 338 kVA / 270 kW
Fuel Capacity 700L / 185Gal
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Cummins 6ZTAA13-G3
Emissions: Tier 1 Rated, for International Use Only
50 Hz Power Rating at 3 Phase
Standby Power Rating: 418.75 kVA / 335 kW
Prime Power Rating: 335 kVA / 268 kW
Powered by Scania DC13 084A
Emissions: Tier 4 Final EPA-Certified for Mobile “NonRoad” Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 385 kVA / 308 kW
Prime Power Rating: 350 kVA / 280 kW
Fuel Capacity 790L / 209Gal
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Perkins 2206A-E13TAG5
Emissions: Tier 1 Rated, for International Use Only
60 Hz Power Rating at 3 Phase
Standby Power Rating: 438 kVA / 350 kW
Prime Power Rating: 400 kVA / 320 kW
Fuel Capacity 8-10 Hr
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Perkins 2206D-E13TAG2
Emissions: Tier 3 EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 438 kVA / 350 kW
Prime Power Rating: 400 kVA / 320 kW
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Perkins 2206D-E13TAG2
Emissions: Tier 3 EPA Certified Emergency Stationary Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 438 kVA / 350 kW
Prime Power Rating: 394 kVA / 315 kW
Leroy Somer Alternator
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Controller Data Sheet
Product Brochure
Powered by Scania DC13 085A
Emissions: Tier 4 Final EPA-Certified for Nonroad Applications
60 Hz Power Rating at 3 Phase
Standby Power Rating: 440 kVA / 352 kW
Prime Power Rating: 400 kVA / 320 kW
Fuel Capacity 1020L / 269.5Gal
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by PSI Engine 14.6L HO
EPA Certified & UL Listed
60 Hz Power Rating at 3 Phase
Standby Power Rating: 437.5 kVA / 350 kW
Prime Power Rating: 394 kVA / 315 kW
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Powered by Perkins 2206C-E13TAG2
Emissions: Tier 1 Rated, for International Use Only
50 Hz Power Rating at 3 Phase
Standby Power Rating: 385 kVA / 308 kW
Prime Power Rating: 350 kVA / 280 kW
Fuel Capacity 8-10 Hr
Generator Set Specifications
Engine Data Sheet
Alternator Specifications
Product Brochure
Showing 1–12 of 28 results